Contact Information

Henan Road King Electromechanical Manufacturing Co., Ltd.
After Sales Service Hotline:

+86-4006-270369

Phone:+86-377-63650816

Mobile:tel:+8613303776917

E-mail:sales001@roadkingem.com

Address: Lihe Industrial Park, Wancheng District, Nanyang City, Henan Province

+
  • LCA1.jpg
  • LCA2.jpg
  • LCA3.jpg
  • LCA4.jpg

LCA Series Burner

Using low-pressure atomizing spray gun, oil adaptability. The integrated burner specially developed for the drying cylinder of the asphalt station has a compact structure and saves installation time.

  • Descriptions
  • Flame stability maintenance simple low-voltage atomization frequency conversion control efficient combustion compact structure

    Key features:

    Using low-pressure atomizing spray gun, oil adaptability.
    The integrated burner specially developed for the drying cylinder of the asphalt station has a compact structure and saves installation time.
    The fuel supply and control lines are arranged in a compact manner for easy system connection.
    The burner host is equipped with rollers, which can move back and forth for convenient maintenance and maintenance.
    The inclination angle of the plane of the chassis of the main machine pulley and the axis of the fire spout can be adjusted by 0-4 degrees.
    Adopt left and right double access door structure, easy to repair.
    Oil pump and fan adopt frequency conversion control technology to improve the reliability of the system;
    The use of annular gas channel, with a special guide gas nozzle and high-efficiency flame stabilization disk, so that the combustion efficiency is higher.
    The gas burner has perfect safety protection measures such as high and low pressure protection, gas leak detection, flame automatic detection, automatic purging and fault quick cut-off.
    The use of special centrifugal fan, multi-layer air distribution structure, so that the flame shape is more stable.
    The fuel valve is self-closing and can be closed in extreme cases to prevent safety accidents.
    The components adopt effective protective measures, which can adapt to the harsh environment of asphalt mixing station, effectively eliminate the hidden trouble and ensure high safety.
    Adopting two control modes of constant frequency and constant pressure, the control precision of air-oil ratio is higher;
    The ignition starts running smoothly and the temperature control precision is high.












     

    Fuel series technical parameters:

    Model

    LCA1000Y

    LCA1500Y

    LCA2000Y

    LCA3000Y

    LCA4000Y

    LCA5000Y

    Maximum output power (MW)

    7

    10.5

    14

    21

    28

    35

    Maximum fuel quantity (kg/h)

    600

    900

    1200

    1800

    2400

    3000

    Blower power (KW)

    7.5

    15

    15

    22

    30

    37

    Oil pump power (KW)

    2.2

    2.2

    2.2

    3

    4

    4

    Compressed air consumption NM3/min

    2

    3

    3

    4

    4

    4

    Supporting asphalt station

    Yield (T/h)

    60-80

    80-120

    120-160

    160-240

    240-320

    320-400

    Regulation ratio

    1:8

    Compressed air pressure

    ≥0.6MPa

    Oil supply pressure

    ≤ 0.03MPa (self-flow to oil inlet)

     Applicable fuel

    Diesel, heavy oil, residual oil

    Gas series technical parameters:

    Model

    LCA1000Q

    LCA1500Q

    LCA2000Q

    LCA3000Q

    LCA4000Q

    LCA5000Q

    Maximum output power (MW)

    7

    10.5

    14

    21

    28

    35

    Maximum gas volume (NM3/h)

    680

    1020

    1360

    2040

    2720

    3400

    Blower power (KW)

    7.5

    15

    15

    22

    30

    37

    Caliber of gas valve group

    DN65

    DN80

    DN80

    DN100

    DN125

    DN125

    Supporting asphalt station

    Yield (T/h)

    60-80

    80-120

    120-160

    160-240

    240-320

    320-400

    Regulation ratio

    1:8

    Gas supply pressure

    45-55KPa

     Applicable fuel

    Natural gas

    Oil and gas dual-purpose series technical parameters:

    Model

    LCA1000YQ

    LCA1500YQ

    LCA2000YQ

    LCA3000YQ

    LCA4000YQ

    LCA5000YQ

    Maximum output power (MW)

    7

    10.5

    14

    21

    28

    35

    Maximum fuel quantity (kg/h)

    600

    900

    1200

    1800

    2400

    3000

    Maximum gas volume (NM3/h)

    680

    1020

    1360

    2040

    2720

    3400

    Blower power (KW)

    7.5

    15

    15

    22

    30

    37

    Oil pump power (KW)

    2.2

    2.2

    2.2

    3

    4

    4

    Compressed air consumption NM3/min

    2

    3

    3

    4

    4

    4

    Supporting asphalt station

    Yield (T/h)

    60-80

    80-120

    120-160

    160-240

    240-320

    320-400

    Regulation ratio

    1:8

    Compressed air pressure

    ≥0.6MPa

    Oil supply pressure

    ≤ 0.03MPa (self-flow to oil inlet of oil pump unit filter)

    Natural gas pressure

    45-55KPa

     Applicable fuel

    Diesel, heavy oil, residual oil, natural gas

Key words:

Message consultation

Leave your contact information to get a free product quote

Submit immediately