Contact Information

Henan Road King Electromechanical Manufacturing Co., Ltd.
After Sales Service Hotline:

+86-4006-270369

Phone:+86-377-63650816

Mobile:tel:+8613303776917

E-mail:sales001@roadkingem.com

Address: Lihe Industrial Park, Wancheng District, Nanyang City, Henan Province

+
  • LCR.jpg
  • LCR1.jpg
  • LCR斜后方45°素材.jpg

LCR Series Burner

Using low-pressure atomizing spray gun, oil adaptability, can be heavy oil direct combustion. The integrated burner specially developed for the drying cylinder of the asphalt station has a compact structure and saves installation time.

  • Descriptions
  • Efficient combustion, simple maintenance, low-voltage atomization, frequency conversion control, safe and reliable, compact structure

     

    Key features:

    Using low-pressure atomizing spray gun, oil adaptability, can be heavy oil direct combustion.
    The integrated burner specially developed for the drying cylinder of the asphalt station has a compact structure and saves installation time.
    The fuel supply and control lines are arranged in a compact manner for easy system connection.
    The burner host is equipped with rollers, which can move back and forth for convenient maintenance and maintenance.
    Adopt left and right double access door structure, easy to repair.
    Oil pump and fan adopt frequency conversion control technology to improve the reliability of the system;
    The use of annular gas channel, with a special guide gas nozzle and high-efficiency flame stabilization disk, so that the combustion efficiency is higher.
    The gas burner has perfect safety protection measures such as high and low pressure protection, gas leak detection, flame automatic detection, automatic purging and fault quick cut-off.
    The use of special axial flow fan, hidden air ring design, the overall shape of the front and back of the left and right symmetrical beauty.
    The fuel valve is self-closing and can be closed in extreme cases to prevent safety accidents.
    The components adopt effective protective measures, which can adapt to the harsh environment of asphalt mixing station, effectively eliminate the hidden trouble and ensure high safety.
    Adopting two control modes of constant frequency and constant pressure, the control precision of air-oil ratio is higher;












     

    Fuel series technical parameters:

    Model

    LCR1000Y

    LCR1500Y

    LCR2000Y

    LCR3000Y

    LCR4000Y

    LCR5000Y

    Maximum output power (MW)

    7.2

    10.5

    14.2

    21.7

    26.8

    33.3

    Maximum fuel quantity (kg/h)

    650

    940

    1280

    1940

    2400

    3000

    Blower power (KW)

    7.5

    11

    15

    22

    30

    37

    Oil pump power (KW)

    2.2

    2.2

    2.2

    3

    4

    4

    Compressed air consumption NM3/min

    2

    3

    3

    4

    4

    4

    Supporting asphalt station

    Yield (T/h)

    60-80

    80-120

    120-160

    160-240

    240-320

    320-400

    Regulation ratio

    1:8

    Compressed air pressure

    ≥0.6MPa

    Oil supply pressure

    ≤ 0.03MPa (self-flow to oil inlet)

     Applicable fuel

    Diesel, heavy oil, residual oil

    Gas series technical parameters:

    Model

    LCR000Q

    LCR1500Q

    LCR2000Q

    LCR3000Q

    LCR4000Q

    LCR5000Q

    Maximum output power (MW)

    7.2

    10.5

    14.2

    21.7

    26.8

    33.3

    Maximum gas volume (NM3/h)

    730

    1060

    1430

    2200

    2700

    3370

    Blower power (KW)

    7.5

    11

    15

    22

    30

    37

    Caliber of gas valve group

    DN65

    DN80

    DN80

    DN100

    DN125

    DN125

    Supporting asphalt station

    Yield (T/h)

    60-80

    80-120

    120-160

    160-240

    240-320

    320-400

    Regulation ratio

    1:8

    Gas supply pressure

    45-55KPa

     Applicable fuel

    Natural gas

    Oil and gas dual-purpose series technical parameters:

    Model

    LCR1000YQ

    LCR1500YQ

    LCR2000YQ

    LCR3000YQ

    LCR4000YQ

    LCR5000YQ

    Maximum output power (MW)

    7.2

    10.5

    14.2

    21.7

    26.8

    33.3

    Maximum fuel quantity (kg/h)

    650

    940

    1280

    1940

    2400

    3000

    Maximum gas volume (NM3/h)

    730

    1060

    1430

    2200

    2700

    3370

    Blower power (KW)

    7.5

    11

    15

    22

    30

    37

    Oil pump power (KW)

    2.2

    2.2

    2.2

    3

    4

    4

    Compressed air consumption NM3/min

    2

    3

    3

    4

    4

    4

    Supporting asphalt station

    Yield (T/h)

    60-80

    80-120

    120-160

    160-240

    240-320

    320-400

    Regulation ratio

    1:8

    Compressed air pressure

    ≥0.6MPa

    Oil supply pressure

    ≤ 0.03MPa (self-flow to oil inlet of oil pump unit filter)

    Natural gas pressure

    45-55KPa

     Applicable fuel

    Diesel, heavy oil, residual oil, natural gas

     

     

     

     

     

     

Key words:

Message consultation

Leave your contact information to get a free product quote

Submit immediately